Vision Lead-acid battery CP1270F2 with 12V and 7Ah
Product information
The Vision CP1270F2 is a high-quality, valve-regulated lead-acid (VRLA) battery with 12 volts rated voltage and 7 Ah capacity. This extremely versatile and reliable all-purpose battery is designed for a long service life in standby mode as well as for light cyclic applications. Equipped with maintenance-free AGM technology and wide 6.35 mm terminals, this battery offers a safe and consistent power supply for a wide range of applications, from emergency power supply in UPS systems to safety-critical alarm systems.
Highlights at a glance
- Universal capacity: 7 Ah at 12 V for a reliable power supply in standard applications.
- VdS approved: G 103134 for safety-related applications
- Long service life: Designed for a service life of up to 5 years in standby mode (float) at 20 °C.
- Maintenance-free: Fully sealed AGM technology with efficient gas recombination eliminates the need for maintenance.
- Compact design: Fits into the most common installation spaces for batteries in this power class.
- Flexible installation: Operation is possible in all positions, with the exception of continuous overhead use.
- Tested quality: Manufactured to the highest quality standards, often with UL certification for use in safety-critical equipment.
Powerful performance for versatile applications
The Vision CP1270F2 provides a rated capacity of 7 Ah with a 20-hour discharge. It is optimised as a general-purpose battery for standby parallel operation, but is equally suitable for applications involving occasional charge and discharge cycles. Its range of applications extends from alarm systems and small UPS systems to emergency lighting and medical technology, where a constant and fail-safe power supply is essential.
Robust technology for demanding environments
Thanks to VRLA technology (Valve Regulated Lead Acid) with AGM system (Absorbent Glass Mat), in which the electrolyte is completely bound in a glass fibre mat, the CP1270F2 is completely maintenance-free and leak-proof. This ensures safe operation even in sensitive electronic environments. The low self-discharge of less than 3 % per month allows for long storage life with high operational readiness. The robust ABS plastic housing offers excellent protection against shocks and vibrations.
Features
| Model | Vision CP1270F2 |
| Battery type | VRLA AGM (Standby / General Purpose) |
| Nominal voltage (V) | 12 |
| Capacity (Ah) | 7 (at 20h rate) |
| Maximum discharge current | 105A (for 5 seconds) |
| Charging voltage (float charge) | 13.5V - 13.8V |
| Charging voltage (cyclic operation) | 14.4V - 15.0V |
| Operating temperature (°C) | Charging: 0 ~ 40 / Discharging: -20 ~ 50 |
| Storage temperature (°C) | -20 ~ 40 |
| Service life | up to 5 years (EUROBAT: Standard Commercial) |
| Dimensions (L/W/H, mm) | 151 x 65 x 99 |
| Weight (kg) | approx. 2.05 |
| Connection | Faston 250 (6.35 mm) |
| Certifications | ISO9001, ISO14001, CE, UL |
FAQs on the Vision CP1270F2 lead-acid battery
What applications is the CP1270F2 suitable for?
The battery is ideal for a wide range of standby and light cyclic applications:
- Security and alarm technology
- Fire alarm systems (FAS)
- Uninterruptible power supplies (UPS)
- Safety lighting and emergency lighting systems
- Medical devices
- Model making and hobby applications
Is the battery maintenance-free?
Yes, thanks to the sealed AGM technology, the battery is completely maintenance-free. No topping up with distilled water is required and it is protected against leakage.
What is the difference between the F1 (4.8mm) and F2 (6.35mm) connection?
The difference lies in the width of the flat plug connection. The F2 connection, also called Faston 250, is 6.35 mm wide, while the F1 connection (Faston 187) is only 4.8 mm wide. The wider F2 connection can transmit higher currents better and is often used in more powerful UPS systems. Please check before purchase which connection type your device requires.
Can this battery replace an old battery in my UPS or alarm system?
Yes, the Vision CP1270F2 is one of the most common replacement batteries. Please compare before purchase the voltage (12V), the capacity (7Ah), the dimensions and especially the connection type (Faston 6.35 mm) with your old battery to ensure compatibility.
Which charging parameters apply to this battery?
Float charge: The recommended voltage at 20 °C is between 13.5 V and 13.8 V.
Cycle charge: For occasional cyclic charging, a voltage between 14.4 V and 15.0 V is recommended.
Maximum charging current: The charging current should not exceed 2.1 A in order to maximise the service life of the battery.
What service life does the CP1270F2 have?
The service life in standby mode (for example in an alarm system) is up to 5 years at an ambient temperature of 20 °C. This corresponds to the EUROBAT category "Standard Commercial".
| Capacity: | 7Ah |
|---|---|
| Connections: | 6.3mm faston |
| Tension: | 12V |
| VDS: | G103134 |
Login