Vision lead-acid battery CP12120F2 with 12V and 12Ah
Description
Product information
The Vision CP12120F2 is a high-quality, valve-regulated lead-acid battery (VRLA) with a nominal voltage of 12 volts and a capacity of 12 Ah. This all-purpose battery from the CP Series was developed for high reliability in standby operation and for light cyclic applications. Equipped with maintenance-free AGM technology, this battery offers safe and long-lasting energy supply for a wide range of applications, from security technology to emergency power supply.
Highlights at a glance
- Reliable capacity: 12 Ah at 12 V for a constant and long-lasting energy supply.
- Long service life: Designed for a service life of up to 5 years in standby operation at 20°C.
- Maintenance-free: Leakproof and sealed AGM technology with a gas recombination rate of over 99%.
- High current capacity: Suitable for devices that require high inrush current for short periods.
- Flexible installation: Operation is possible in all positions, except permanent upside-down use.
- Tested quality: Manufactured according to ISO9001 and ISO14001 standards for consistently high quality.
Powerful performance for versatile applications
The Vision CP12120F2 provides a capacity of 12 Ah at a 20-hour discharge. It is designed as a general-purpose battery and is effective both in standby parallel operation (float) and with occasional cyclical discharges. With a maximum discharge current of 180A for 5 seconds, this battery is also ideally suited for short-term power peaks, as required in UPS systems or in security technology.
Robust technology for demanding environments
Thanks to VRLA technology (Valve Regulated Lead Acid) with AGM system (Absorbent Glass Mat), where the electrolyte is bound in a glass fibre mat, the CP12120F2 is absolutely maintenance-free and leakproof. This ensures safe operation in sensitive environments. The low self-discharge rate of around 3% per month enables long shelf life with high operational readiness. The robust ABS plastic housing offers excellent protection against mechanical influences.
Features
| Model | Vision CP12120F2 |
| Battery type | VRLA AGM (standby / general purpose) |
| Nominal voltage (V) | 12 |
| Capacity (Ah) | 12 (at 20h rate) |
| Maximum discharge current | 180A (for 5 seconds) |
| Charging voltage (float charge) | 13.5V - 13.8V |
| Charging voltage (cyclic operation) | 14.4V - 15.0V |
| Operating temperature (°C) | Charge: 0 ~ 40 / Discharge: -20 ~ 50 |
| Storage temperature (°C) | -20 ~ 40 |
| Service life | up to 5 years (EUROBAT: Standard Commercial) |
| Dimensions (L/W/H, mm) | 151 x 98 x 98 |
| Weight (kg) | approx. 3.5 |
| Connection | Faston 250 (6.35 mm) |
| Certifications | ISO9001, ISO14001, CE, UL |
FAQs about the Vision CP12120F2 lead-acid battery
For which applications is the CP12120F2 suitable?
The battery is ideal for a wide range of standby and light cyclic applications:
- Uninterruptible power supplies (UPS)
- Security and alarm technology
- Fire alarm systems (BMA)
- Emergency lighting
- Medical devices
- Telecommunication systems
Is the battery maintenance-free?
Yes, thanks to the sealed AGM technology, the battery is completely maintenance-free. No topping up with distilled water is required and it is protected against leaking.
What is the service life of the CP12120F2?
The service life in standby operation (e.g. in a UPS system) is up to 5 years at an ambient temperature of 20°C and thus corresponds to the EUROBAT category "Standard Commercial".
What is the difference between this battery and a purely cyclic type?
The CP12120F2 is a general-purpose battery optimised for standby operation with occasional discharges. A purely cyclic battery is specially designed for frequent and deep discharges (e.g. in an electric wheelchair). For such applications, a cyclic type would deliver a longer service life.
What are the charging parameters for this battery?
Float charge: The recommended voltage at 20°C is between 13.5V and 13.8V.
Cyclic charge: For occasional cyclic charging a voltage between 14.4V and 15.0V is recommended.
Maximum charging current: The charging current should not exceed 3.6 A to avoid impairing service life.
What are the temperature ranges and storage conditions?
Charging: 0°C to +40°C
Discharging: -20°C to +50°C
Storage (fully charged): -20°C to +40°C
Self-discharge: about 3% per month at 20°C. For longer storage, it is recommended to recharge the battery every 6 months.
Properties
| Capacity: | 12Ah |
|---|---|
| Tension: | 12V |
| VDS: | G104011 |
Documents 1
Reviews 0
Login