The XCELL XP7-12 is a valve-regulated AGM battery with 12 volts and a rated capacity of 7 Ah (C20). It impresses with its compact dimensions, high operational reliability and long service life. Thanks to its robust construction and low self-discharge, it is ideally suited for use in security and emergency power systems, medical technology, measurement and control technology, telecommunications, and in numerous mobile and stationary applications.

Highlights at a glance

  • Compact power: 12 V, 7.0 Ah (20h)
  • VdS approved: G 120023 for safety-related applications
  • Flexible usage: Any operating position is possible (except permanently upside down)
  • Long-lasting: Up to 5 years design life at 20 °C
  • High reliability: Low self-discharge <3 % per month at 25 °C
  • Robust housing: ABS UL94 HB

Reliable power supply for a wide range of applications

XCELL ’s XP7-12 delivers consistent performance even under demanding conditions. AGM technology ensures efficient gas recombination, making the battery virtually maintenance-free. With a maximum discharge current capacity of 105 A (5 seconds), it is also suitable for applications with short-term peak loads.

Efficiency meets durability

In standby mode, the battery should be charged to a voltage of 2.25–2.30 V/cell. For cyclic operation, a charging voltage of 2.45–2.50 V/cell is recommended. The temperature compensation is –3 mV/cell/°C in standby mode and –4 mV/cell/°C in cyclic operation. The recommended maximum current is 0.3C (approx. 2.1 A). In cyclic use, the battery achieves several hundred charge and discharge cycles, depending on the depth of discharge.

Technology for flexible applications

The operating temperature range of the cells is between –15 °C and +50 °C during charging. During discharge, it is –20 °C to +60 °C, and during storage –20 °C to +50 °C. T1 or T2 plug-in connectors are available for the electrical connection. The recommended tightening torque for this is between 2 and 3 Newton metres. Each cell is also equipped with a safety valve, which further enhances operational safety.

Features

 
ModelXCELL XP7-12
Battery typeVRLA AGM (Standby / General Purpose)
Nominal voltage (V)12
Capacity (Ah)7.0 (at 20-hour rate)
Maximum discharge current105A (for 5 seconds)
Charging voltage (trickle charge)13.5V - 13.8V
Charging voltage (cyclic operation)14.4V - 15.0V
Operating temperature (°C)Charging: 0 ~ 40 / Discharging: -20 ~ 50
Storage temperature (°C)-20 ~ 40
Service lifeup to 5 years (EUROBAT: Standard Commercial)
Dimensions (L/W/H, mm)151 x 65 x 100
Weight (kg)approx. 2.1
ConnectionFaston 187 (4.8 mm)
CertificationsISO9001, CE, UL
 

FAQ on the XCELL XP7-12 industrial battery

For which applications is the XP7-12 ideally suited?

The XCELL XP7-12 is ideal for emergency power supply, security and fire alarm systems, medical technology, telecommunications, measurement and control technology, as well as mobile devices with cyclic energy requirements.

How cycle-stable is the XP7-12?

At a 30% depth of discharge, the battery achieves over 1,000 charge and discharge cycles. At higher depths of discharge, the service life is reduced accordingly, but remains in the range of several hundred cycles.

What are the specific safety features?

The battery is equipped with pressure relief valves. Like all VRLA batteries, it may release small amounts of hydrogen. It should therefore not be operated in airtight enclosures and adequate ventilation must be ensured.

Which chargers are suitable for the XP7-12?

Constant-voltage chargers designed for VRLA AGM batteries are recommended. Correct setting of the charging voltage and temperature compensation is crucial for a long service life.

How is the battery installed?

The battery can be installed in any position except permanently upside down. Connection is via T1 or T2 plug-in terminals with a tightening torque of 2–3 Nm.



 
Properties
Capacity: 7Ah
Connections: 4.8mm Faston
Tension: 12V
VDS: VDS No. G 120023
Documents 1
Reviews 0

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Customers also bought

XCEXP1212F2
XCELL XP12-12F2 lead-acid battery lead-acid battery with VdS approval – 12 V and 12 Ah

The XCELL XP12-12F2 is a reliable, valve-regulated lead-acid battery with 12 volts and a capacity of 12 Ah. With 6.3 mm Faston plug-in terminals, compact dimensions and VdS certification (G120034), it is ideal for safety-critical applications such as fire and burglar alarm systems, UPS systems, and medical and industrial equipment. Its leak-proof AGM technology ensures a maintenance-free and long-lasting power supply.Highlights at a glanceVdS approved: G 120034 for safety-related applicationsCompact design: Measuring just 151 x 98 x 95 mm and weighing approx. 4.1 kgReliable performance: 12 Ah capacity at a 20-hour discharge rateHigh discharge current: Up to 180 A (5 sec.) for peak loadsLong-lasting: Up to 5 years’ service life at 25 °C in standby modePowerful performance for demanding applicationsThanks to its robust construction and consistent current output, the XP12-12F2 is suitable for a wide range of applications: from safety-critical systems and telecommunications to medical equipment. The Faston connectors (6.3 mm) enable seamless integration into existing setups. Even during short-term load peaks, the battery reliably delivers power with a discharge current of up to 180 A for 5 seconds.Efficient energy and reliable service lifeAGM technology ensures maintenance-free operation and high reliability. With a float life of up to 5 years (at 25 °C), the battery is characterised by low self-discharge of less than 3% per month, meaning it is ready for immediate use even after prolonged storage. It also impresses with good performance at extreme temperatures ranging from -15 °C (charging) to +60 °C (discharging).Technology for industrial and safety-critical applicationsThe XP12-12F2 features a flame-retardant ABS housing (in accordance with UL94-HB/UL94-V0) and complies with international standards such as ISO 9001, ISO 14001 and OHSAS 18001. The charging voltage is 2.25 – 2.30 V/cell (equivalent to 13.5 – 13.8 V) in standby mode and 2.45 – 2.50 V/cell (equivalent to 14.7 – 15.0 V) in cycle mode at an ambient temperature of 25 °C. Automatic temperature compensation of –3 to –4 mV/°C/cell is integrated.Features  ModelXCELL XP12-12F2 VdS Battery typeVRLA AGM (security technology) Nominal voltage (V)12 Capacity (Ah)12 (at a 20-hour rate) Maximum discharge current180A (for 5 seconds) Charging voltage (trickle charge)13.5V - 13.8V Charging voltage (cyclic operation)14.4V - 15.0V Operating temperature (°C)Charging: 0 ~ 40 / Discharging: -20 ~ 50 Storage temperature (°C)-20 ~ 40 Service lifeup to 5 years (EUROBAT: Standard Commercial) Dimensions (L/W/H, mm)151 x 98 x 100 Weight (kg)approx. 3.6 ConnectionFaston 250 (6.35 mm) CertificationsVdS, ISO9001, CE, UL  FAQs on the XCELL XP12-12F2 lead-acid batteryHow long does the XCELL XP12-12F2 last in standby mode?Under ideal conditions (25 °C ambient temperature), the expected service life in standby mode is up to 5 years.Is the battery VdS-certified?Yes, the battery has VdS approval with the number G120034 and is therefore suitable for safety-critical applications.What temperature range is the battery suitable for?The battery is designed for a charging range of –15 °C to +50 °C and a discharging range of –20 °C to +60 °C.What is the self-discharge rate?At 25 °C, the battery’s self-discharge rate is less than 3 % per month. It is recommended that the battery be recharged if it has been stored for longer than six months.What charging parameters must be observed?For standby operation, the charging voltage is 13.5–13.8 V. In cyclic operation, it should be 14.7–15.0 V. The temperature compensation is –3 mV/°C/cell in standby operation and –4 mV/°C/cell in cyclic operation.For which applications is this battery particularly suitable?It is suitable for photovoltaic systems, UPS systems, emergency lighting, telecommunications and security technology, alarm and hazard warning systems, as well as for hobby and camping use. However, it is not suitable for starting or traction applications.

XCEXP2612
XCELL XP26-12 lead-acid battery with VdS approval - 12 V and 26 Ah

The XCELL XP26-12 is a powerful, maintenance-free 12-volt lead-acid battery with a capacity of 26 Ah (20-hour rate), characterised by its long service life. It has been specially developed for reliable, safety-critical and industrial applications. Thanks to its robust AGM technology and M5 inlay terminals, it delivers a high current output. The battery is also VdS-certified (G115073).Highlights at a glanceVdS approved: G 115073 for safety-related applicationsPowerful performance: 26 Ah capacity at a 20-hour discharge rateHigh current output: Up to 390 A discharge current (5 seconds)Long-lasting: Up to 5 years’ service life in standby mode at 25 °CMaintenance-free: Leak-proof AGM technology (VRLA)Powerful performance for demanding applicationsThe XP26-12 ensures a constant and reliable power supply, even during short-term load peaks, with a discharge current of up to 390 A for 5 seconds. With its compact dimensions (165 × 176 × 127 mm) and low weight of approx. 7.9 kg, it is ideal for mobile devices, emergency power supply systems, telecommunications, safety lighting and other industrial applications.Efficient and long-lasting power supplyAGM technology ensures maintenance-free operation with minimal self-discharge of less than 3% per month at 25 °C. A voltage of 13.60–13.80 V is recommended for continuous operation (float charging), whilst 14.50–14.90 V is ideal for cyclic operation. Integrated temperature compensation ensures the efficiency of the charging power regardless of the ambient temperature. The maximum charging power is 7.8 A.Technology for reliable safetyThe battery is fitted with a flame-retardant casing in accordance with UL94-HB/V0 and complies with international standards such as CE, UL and ISO 9001. The design allows for safe operation over several years in standby mode, provided proper maintenance is carried out and ambient temperature conditions are met. Even under difficult conditions, the battery maintains a stable capacity output, approximately 85% at 0 °C and 65% at –15 °C.Features  ModelXCELL XP26-12 VdS Battery typeVRLA AGM (security technology) Nominal voltage (V)12 Capacity (Ah)26 (at a 20-hour rate) Maximum discharge current390A (for 5 seconds) Charging voltage (float charge)13.5V - 13.8V Charging voltage (cyclic operation)14.4V - 15.0V Operating temperature (°C)Charging: 0 ~ 40 / Discharging: -20 ~ 50 Storage temperature (°C)-20 ~ 40 Service lifeup to 5 years (EUROBAT: High Performance) Dimensions (L/W/H, mm)166 x 175 x 125 Weight (kg)approx. 8.6 ConnectionM5 screw connection CertificationsVdS, ISO9001, CE, UL  FAQs on the XCELL XP26-12What is the service life of the XCELL XP26-12 battery?Depending on operating conditions, the float service life is 3 to 5 years at an ambient temperature of 25 °C.What is the XCELL XP26-12 suitable for?The battery is suitable for safety-critical systems (e.g. fire and burglar alarm systems), UPS systems, telecommunications equipment, medical technology and other industrial applications.Is the XCELL XP26-12 battery VdS-certified?Yes, the XCELL XP26-12 holds VdS approval with the number G115073.What is the self-discharge rate?Self-discharge is less than 3% per month at 25 °C.What charging parameters should be observed?A voltage of 13.60 to 13.80 V is recommended for standby operation. In cyclic operation, the voltage is 14.50 to 14.90 V. The maximum charging current should not exceed 7.8 A.Is the battery maintenance-free, leak-proof and usable in any position?Yes, the XP 26‑12 VDS is maintenance-free, sealed, leak-proof and can be operated in any position. 

XCEXP1812
XCELL XP18-12 lead-acid battery with 12 V and 18 Ah VdS approval

The XCELL XP18-12 is a high-performance, maintenance-free lead-acid battery renowned for its reliability and longevity. Based on proven AGM (Absorbent Glass Mat) technology, this battery offers a nominal voltage of 12 V and a capacity of 18 Ah. It has been specially developed for demanding stationary and cyclic applications where a constant and reliable power supply is crucial. Thanks to its sealed VRLA design, it is leak-proof and can be operated in any position.Highlights at a glanceReliable performance: 18 Ah capacity at 12 V, which corresponds to a total energy of 216 Wh.Long-lasting: Designed for a service life of up to 5 years in accordance with the Eurobat classification.Maintenance-free: VRLA AGM technology eliminates the need for topping up with water.Safe and flexible: Fully sealed, leak-proof and suitable for installation in any orientation.Low self-discharge: Ideal for standby operation and seasonal use.VdS approved: G 115072 for safety-related applicationsReliable power for critical applicationsThe XCELL XP18-12 is the ideal power solution for systems where reliability is paramount. With its standard dimensions of 181 x 77 x 167 mm and a weight of approximately 5.4 kg, it can be easily integrated as a replacement for existing batteries in a wide range of devices. Its primary applications include uninterruptible power supplies (UPS), security and alarm systems, emergency lighting systems, and applications in medical and rehabilitation technology. The wide operating temperature range ensures stable performance even under demanding environmental conditions.Efficiency and safety thanks to AGM technologyThe AGM technology of the XCELL XP18-12 binds the electrolyte within a glass fibre mat. This design not only prevents acid leakage but also ensures high vibration resistance and excellent cycle stability compared to conventional lead-acid batteries. As no gassing occurs during normal operation, the battery can be used safely indoors and in enclosures without special ventilation. This maximises user safety and reduces maintenance requirements to a minimum.Proven and robust lead-acid AGM technologyUnlike open lead-acid batteries, the XP18-12 is valve-regulated and sealed thanks to its VRLA (Valve Regulated Lead Acid) design. This enables internal gas recombination and ensures consistently high performance throughout the entire service life. The lead-calcium grid plates used contribute to a very low self-discharge rate, making the battery ideal for standby operation or for applications with prolonged periods of inactivity.Features  ModelXCELL XP18-12 VdS Battery typeVRLA AGM (security technology) Nominal voltage (V)12 Capacity (Ah)18 (at a 20-hour rate) Maximum discharge current270A (for 5 seconds) Charging voltage (trickle charge)13.5V - 13.8V Charging voltage (cyclic operation)14.4V - 15.0V Operating temperature (°C)Charging: 0 ~ 40 / Discharging: -20 ~ 50 Storage temperature (°C)-20 ~ 40 Service lifeup to 10 years (EUROBAT: High Performance) Dimensions (L/W/H, mm)181 x 77 x 167 Weight (kg)approx. 5.6 ConnectionM5 screw connection CertificationsVdS, ISO9001, CE, UL  FAQs on the XCELL XP18-12 lead-acid batteryWhat does the term AGM mean?AGM stands for "Absorbent Glass Mat". In this technology, the battery electrolyte is bound within a glass fibre mat. This makes the battery leak-proof, maintenance-free and highly resistant to vibrations.What applications is the XP18-12 battery suitable for?The battery is ideal for uninterruptible power supplies (UPS), alarm systems, fire alarm control panels, emergency lighting systems, as well as for medical and rehabilitation equipment such as patient lifts or electric wheelchairs.What is the expected service life of the battery?The XCELL XP18-12 is designed for a service life of up to 5 years in standby mode in accordance with the Eurobat classification. The actual service life depends heavily on the application, operating temperature and depth of discharge.Can multiple XP18-12 batteries be connected together?Yes, you can connect several batteries of this type together. For a higher voltage (e.g. 24 V), connect two batteries in series. For a higher capacity, connect the batteries in parallel. Please only use batteries of the same type, age and charge level for this purpose.Is the battery truly maintenance-free?Yes, thanks to its sealed VRLA AGM design, the battery is completely maintenance-free. No top-up of distilled water is required throughout its entire service life.How should the battery be stored when not in use?Please store the battery in a cool, dry place and ensure it is fully charged. Due to the low rate of self-discharge, the charge level should be checked every six months and the battery recharged if necessary to prevent deep discharge. 

XCEXP2.312
XCELL XP2.3-12 lead-acid battery with VdS approval – 12 V and 2.3 Ah

The XCELL XP2.3-12 is a slim 12-volt AGM lead-acid battery with a nominal capacity of 2.3 Ah. It provides a reliable power supply for safety-critical and industrial applications and, with VdS G 115071 certification, meets the requirements for professional use.Highlights at a glanceReliable capacity: 2.3 Ah at 20 hours to 10.5 VVdS approved: G 115071 for safety-related applicationsPower reserve: up to 34.5 A discharge current for 5 secondsSlim design: 178 x 35 x 67 mm, weighing approx. 0.9 kgMaintenance-free: Valve-regulated AGM technology with ABS housingLow self-discharge: 91 per cent residual capacity after 3 months at 25 °CApplications and performanceThe XP2.3-12 is suitable for alarm and security technology, emergency lighting, fire alarm systems, communication and measuring equipment, as well as control and regulation technology. The internal impedance of approx. 60 mΩ (fully charged, 25 °C) ensures a stable power supply, even during brief load peaks.Charging parameters and operationFor standby operation, 13.60 to 13.80 V at 25 °C is recommended, with temperature compensation of minus 18 mV per °C. In cyclic operation, the final charging voltages range from 14.50 to 14.90 V at 25 °C, with compensation of minus 30 mV per °C. The maximum charging current is 0.69 A. The permissible temperature range is from minus 15 °C to plus 50 °C during discharge, from minus 10 °C to plus 50 °C during charging, and from minus 20 °C to plus 50 °C for storage.Dimensions and connectionsThe T1 copper flat plug connectors enable quick integration into existing systems. Thanks to its compact, elongated design, the battery fits particularly well in narrow enclosures and racks.Features  ModelXCELL XP2.3-12 VdS Battery typeVRLA AGM (security technology) Nominal voltage (V)12 Capacity (Ah)2.3 (at 20-hour rate) Maximum discharge current34.5A (for 5 seconds) Charging voltage (trickle charge)13.5V - 13.8V Charging voltage (cyclic operation)14.4V - 15.0V Operating temperature (°C)Charging: 0 ~ 40 / Discharging: -20 ~ 50 Storage temperature (°C)-20 ~ 40 Service lifeup to 5 years (EUROBAT: Standard Commercial) Dimensions (L/W/H, mm)178 x 35 x 66 Weight (kg)approx. 0.94 ConnectionFaston 187 (4,8 mm) CertificationsVdS, ISO9001, CE, UL  FAQs on the XCELL XP2.3-12What is the expected service life of the XP2.3-12 in standby mode?At 20 °C, the XP2.3-12 battery is designed for 3 to 5 years of float operation. Regular testing cycles and the correct charging voltage increase availability.For which applications is the XP2.3-12 battery suitable?Preferred for safety systems such as fire alarm and intruder alarm systems, emergency lighting, communication and measuring equipment, as well as control systems with a 12-volt supply.What charging voltages must be observed?Float 13.60 to 13.80 V at 25 °C, cyclic operation 14.50 to 14.90 V. Please note the relevant temperature compensation.What is the self-discharge rate?At 25 °C, approximately 91 per cent of capacity remains after 3 months, 82 per cent after 6 months and 65 per cent after 12 months of storage.What connections are available on the XP2.3-12?The XP2.3-12 features T1 copper flat plug connectors for quick and secure installation. 

XCEXP1.212
XCELL XP1.2-12 lead-acid battery with VdS approval – 12 V and 1.2 Ah

The XCELL XP1.2-12 is a compact 12-volt AGM lead-acid battery with a nominal capacity of 1.2 Ah. It reliably supplies energy in safety-related devices and industrial applications, impresses with easy integration and defined charging parameters for standby and cyclic operation.Highlights at a glanceCompact and lightweight: 97 x 43 x 58 mm at approx. 0.54 kgVdS approved: G 114095 for safety applicationsMaintenance-free thanks to AGM technology and valve-regulated constructionClear charging windows: Float 13.60 to 13.80 V, Cycle 14.50 to 14.90 VSolid power reserve: up to 18 A discharge current for 5 secondsUse and PerformanceThe XP1.2-12 is designed for alarm and security technology, emergency lighting, communication and measuring devices as well as small control units. The internal impedance of approx. 90 mΩ supports stable voltage supply, even during short load peaks. The permissible discharge range from −15 °C to +50 °C enables operation in different environments.Efficiency and Service LifeIn float operation, an expected service life of 3 to 5 years at 20 °C is envisaged. The self-discharge is low: at 25 °C approx. 91 percent capacity remains after 3 months, 82 percent after 6 months and 65 percent after 12 months of storage. This means the battery remains reliably available even after idle periods.Installation and Charging RecommendationsThe battery has T1 terminals for quick, secure installation. For standby operation, a charging voltage of 13.60 to 13.80 V at 25 °C with temperature compensation of −18 mV per °C is recommended. In cyclic operation, 14.50 to 14.90 V at 25 °C with −30 mV per °C compensation applies. The maximum charging current is 0.36 A.Features  ModelXCELL XP1.2-12 VdS Battery typeVRLA AGM (safety technology) Nominal voltage (V)12 Capacity (Ah)1.2 (at 20h rate) Maximum discharge current18A (for 5 seconds) Charging voltage (standby charge)13.5V - 13.8V Charging voltage (cyclic operation)14.4V - 15.0V Operating temperature (°C)Charge: 0 ~ 40 / Discharge: -20 ~ 50 Storage temperature (°C)-20 ~ 40 Service lifeup to 5 years (EUROBAT: Standard Commercial) Dimensions (L/W/H, mm)97 x 43 x 58 Weight (kg)approx. 0.57 ConnectionFaston 187 (4.8 mm) CertificationsVdS, ISO9001, CE, UL  FAQs about the XCELL XP1.2-12What is the expected service life of the XP1.2-12 in standby operation?At 20 °C, 3 to 5 years in float operation is envisaged. Regular functional checks and appropriate charging voltage increase availability.For which applications is the XP1.2-12 battery suitable?Preferred for alarm and signalling systems, emergency lighting, communication and measuring devices as well as compact controllers with 12-volt supply.Which charging voltages should be used?In float charge operation, the voltage should be between 13.60 V and 13.80 V at 25 °C. In cyclic operation, the recommended voltage range is 14.50 V to 14.90 V. Please note the temperature compensation.What is the self-discharge rate?At 25 °C, approx. 91 percent of the capacity remains after 3 months, approx. 82 percent after 6 months, and approx. 65 percent after 12 months storage.Which terminals are present on the battery?T1 flat plug terminals for quick integration into devices and assemblies.Which VdS approval does the battery have and is it system-bound?The battery is VdS-approved under number G114095 and the approval is not system-bound. 

XCEXP3.412
XCELL XP3.4-12 lead-acid battery with VdS approval – 12 V and 3.4 Ah

The XCELL XP3.4-12 is a compact 12-volt AGM lead-acid battery with a rated capacity of 3.4 Ah. It delivers stable performance in safety-critical and industrial applications and can be quickly integrated thanks to T1 flat plug terminals. VdS approval and ISO 9001-certified manufacturing underline its suitability for professional use.Highlights at a glance3.4 Ah during a 20-hour discharge up to 10.5 VVdS approved: G 125002 for safety-related applicationsLow internal resistance of approx. 45 mΩ for reliable current deliverySlim design: 134 x 67 x 66.5 mm, weighing approx. 1.20 kgMaintenance-free thanks to VRLA-AGM and robust ABS casingPerformance for demanding applicationsThe XP3.4-12 ensures a reliable 12 V power supply for fire and burglar alarm systems, emergency and safety lighting, control and regulation technology, as well as measurement and communication devices. Even short-term load peaks are absorbed smoothly.Efficiency and service lifeThe usable capacity is maintained across a wide temperature range: at 40 °C it is 103 per cent, at 25 °C 100 per cent and at 0 °C still 86 per cent. VRLA-AGM technology ensures minimal maintenance and consistent performance throughout the entire service life.Technology and installationT1 flat-pin connectors enable fast, reverse-polarity-protected integration. In standby mode, a charging voltage of 13.5 to 13.8 V at 25 °C is recommended, with temperature compensation of minus 20 mV per °C. In cyclic operation, 14.4 to 15.0 V at 25 °C with minus 30 mV per °C. The initial charging current in cyclic operation should be less than 1.02 A.Properties  ModelXCELL XP3.4-12 VdS Battery typeVRLA AGM (security technology) Nominal voltage (V)12 Capacity (Ah)3.4 (at 20-hour rate) Maximum discharge current51A (for 5 seconds) Charging voltage (trickle charge)13.5V - 13.8V Charging voltage (cyclic operation)14.4V - 15.0V Operating temperature (°C)Charging: 0 ~ 40 / Discharging: -20 ~ 50 Storage temperature (°C)-20 ~ 40 Service lifeup to 5 years (EUROBAT: Standard Commercial) Dimensions (L/W/H, mm)134 x 67 x 66 Weight (kg)approx. 1.3 ConnectionFaston 187 (4.8 mm) CertificationsVdS, ISO9001, CE, UL  FAQs about the XCELL XP3.4-12What is the XP3.4-12 battery particularly suitable for?For safety systems such as fire and smoke detection systems, emergency and safety lighting, control systems, communication and measuring equipment, as well as other 12-volt systems with moderate to medium loads.What charging voltages must be observed?In standby mode, the voltage at 25 °C is 13.5 to 13.8 V. In cyclic operation, it is between 14.4 and 15.0 V. Please note the respective temperature compensation.What connections are available on the XP3.4-12?T1 flat plug connectors for quick, reverse-polarity-protected installation in existing cable harnesses.Is the battery maintenance-free?VRLA-AGM technology enables leak-proof, low-gassing and virtually maintenance-free operation.Are there different versions with and without VdS approval?Yes, in addition to the VdS version with the designation G 125002, retailers also offer the standard variant without VdS approval, which should be taken into account when selecting a product.How does temperature affect capacitance?The capacity is temperature-dependent and amounts to approximately 103 per cent at 40 degrees Celsius, 100 per cent at 25 degrees Celsius and 86 per cent of the nominal value at 0 degrees Celsius.