Vision Lead-acid battery CP1250A with 12V and 5.2Ah
Description
Product information
The Vision CP1250A is a high-quality, valve-regulated lead-acid battery (VRLA) with 12 volt nominal voltage and 5.2 Ah capacity. This compact and reliable all-purpose battery is designed for a long service life in standby mode as well as for light cyclic requirements. Equipped with maintenance-free AGM technology, this battery provides a safe and reliable power supply for a wide range of applications, especially in safety and medical technology as well as in emergency lighting systems.
Highlights at a glance
- Reliable capacity: 5.2 Ah at 12 V for a reliable power supply with minimal space requirements.
- Long service life: Designed for a service life of up to 5 years in standby mode (float) at 20 °C.
- Maintenance-free: Fully sealed AGM technology with efficient gas recombination eliminates the need for maintenance.
- Compact design: Ideal for installation in enclosures with limited space.
- Flexible installation: Operation is possible in all positions, except for permanent overhead installation.
- Tested quality: Manufactured to the highest quality standards, ideal for use in safety-relevant devices.
Powerful performance for versatile applications
The Vision CP1250A delivers a nominal capacity of 5.2 Ah with a 20-hour discharge. It is optimised as a general purpose battery for standby parallel operation but is also suitable for applications with occasional charging and discharging cycles. Its field of application ranges from alarm systems and UPS units to mobile medical equipment, where a constant and failure-proof power supply is essential.
Robust technology for demanding environments
Thanks to the VRLA technology (Valve Regulated Lead Acid) with AGM system (Absorbent Glass Mat), in which the electrolyte is completely bound in a glass fibre mat, the CP1250A is absolutely maintenance-free and leak-proof. This ensures safe operation even in sensitive electronic environments. The low self-discharge of less than 3% per month enables a long shelf life with high operational readiness. The robust ABS plastic housing provides excellent protection from shocks and vibrations.
Features
| Model | Vision CP1250A |
| Battery type | VRLA AGM (standby / general purpose) |
| Nominal voltage (V) | 12 |
| Capacity (Ah) | 5.2 (at 20h rate) |
| Maximum discharge current | 78A (for 5 seconds) |
| Charging voltage (standby charge) | 13.5V - 13.8V |
| Charging voltage (cyclic operation) | 14.4V - 15.0V |
| Operating temperature (°C) | Charging: 0 ~ 40 / Discharging: -20 ~ 50 |
| Storage temperature (°C) | -20 ~ 40 |
| Service life | up to 5 years (EUROBAT: Standard Commercial) |
| Dimensions (L/W/H, mm) | 90 x 70 x 107 |
| Weight (kg) | approx. 1.8 |
| Connection | Faston 187 (4.8 mm) |
| Certifications | ISO9001, ISO14001, CE, UL |
FAQs about the Vision CP1250A lead-acid battery
For which applications is the CP1250A suitable?
The battery is ideal for a wide range of standby and light cyclic applications:
- Security and alarm technology
- Fire alarm systems (BMA)
- Smaller uninterruptible power supplies (UPS)
- Safety lighting and emergency lighting systems
- Medical devices (e.g. monitors, pumps)
- Model making and hobby applications
Is the battery maintenance-free?
Yes, thanks to the sealed AGM technology, the battery is completely maintenance-free. No topping up with distilled water is required and it is protected against leakage.
What is the service life of the CP1250A?
The service life in standby mode (for example in an alarm system) is up to 5 years at an ambient temperature of 20 °C. This corresponds to the EUROBAT category “Standard Commercial”.
Can this battery replace an old battery in my alarm system?
Yes, the Vision CP1250A is a very common replacement battery for many alarm systems and emergency lighting systems. Please compare the voltage (12V), the capacity (approx. 5Ah), the dimensions and the connection type (Faston 4.8 mm) with your old battery before purchase to ensure compatibility.
What are the charging parameters for this battery?
Float charge: The recommended voltage at 20 °C is between 13.5 V and 13.8 V.
Cyclic charge: For occasional cyclic charging, a voltage between 14.4 V and 15.0 V is recommended.
Maximum charge current: The charging current should not exceed 1.5 A to maximise the battery's service life.
What does the connection type Faston 187 mean?
Faston 187 refers to the type of connection. These are flat plug connections with a width of 4.8 mm (0.187 inch). Cables are simply plugged onto these contacts, allowing quick and tool-free installation.