Vision Lead-acid battery CP1232 with 12V and 3.2Ah
Description
Product information
The Vision CP1232 is a high-quality, valve-regulated lead-acid battery (VRLA) with 12 volts nominal voltage and 3.2 Ah capacity. This compact and reliable all-purpose battery is designed for a long service life in standby operation as well as for light cyclic requirements. Equipped with maintenance-free AGM technology, this battery provides safe and reliable power supply for a wide variety of applications, especially in safety and medical technology as well as in emergency lighting systems.
Highlights at a Glance
- Compact energy: 3.2 Ah capacity at 12 V for reliable power supply in a compact size.
- Long service life: Designed for a lifetime of up to 5 years in standby operation (float) at 20 °C.
- Maintenance-free: Completely sealed AGM technology with efficient gas recombination makes maintenance unnecessary.
- Reliable performance: Provides stable voltage and low self-discharge.
- Flexible installation: Can be operated in all positions except for continuous upside-down operation.
- Tested quality: Manufactured according to the highest quality standards, ideal for use in safety-relevant equipment.
Powerful Performance for Versatile Applications
The Vision CP1232 delivers a nominal capacity of 3.2 Ah during a 20-hour discharge. It is optimised as a general purpose battery for parallel standby operation, but is also suitable for applications with occasional charge and discharge cycles. Its range of application extends from alarm systems and UPS systems to mobile medical devices where a constant and fail-safe power supply is essential.
Robust Technology for Demanding Environments
Thanks to VRLA technology (Valve Regulated Lead Acid) with AGM system (Absorbent Glass Mat), in which the electrolyte is completely bound in a glass fibre mat, the CP1232 is absolutely maintenance-free and leak-proof. This ensures safe operation even in sensitive electronic environments. The low self-discharge rate of less than 3% per month allows for long storage with high operational readiness. The robust ABS plastic housing provides excellent protection against shocks and vibrations.
Features
| Model | Vision CP1232 |
| Battery type | VRLA AGM (standby / general purpose) |
| Nominal voltage (V) | 12 |
| Capacity (Ah) | 3.2 (at 20h rate) |
| Maximum discharge current | 48A (for 5 seconds) |
| Charge voltage (float charge) | 13.5V - 13.8V |
| Charge voltage (cyclic operation) | 14.4V - 15.0V |
| Operating temperature (°C) | Charge: 0 ~ 40 / Discharge: -20 ~ 50 |
| Storage temperature (°C) | -20 ~ 40 |
| Service life | up to 5 years (EUROBAT: Standard Commercial) |
| Dimensions (L/W/H, mm) | 134 x 67 x 66 |
| Weight (kg) | ca. 1.3 |
| Connection | Faston 187 (4.8 mm) |
| Certifications | ISO9001, ISO14001, CE, UL |
FAQs about the Vision CP1232 lead-acid battery
For which applications is the CP1232 suitable?
The battery is ideal for a wide range of standby and light cyclic applications:
- Security and alarm technology
- Fire alarm systems (BMA)
- Smaller uninterruptible power supplies (UPS)
- Safety lighting and emergency lighting systems
- Medical devices (e.g. monitors, pumps)
- Model building and hobby applications
Is the battery maintenance-free?
Yes, thanks to the sealed AGM technology, the battery is completely maintenance-free. No topping up with distilled water is necessary and it is leak-proof.
What is the service life of the CP1232?
The service life in standby operation (for example in an alarm system) is up to 5 years at an ambient temperature of 20 °C. This corresponds to the EUROBAT category "Standard Commercial".
Can this battery replace an old battery in my alarm system?
Yes, the Vision CP1232 is a very common replacement battery for many alarm systems and emergency lighting systems. Please compare the voltage (12V), capacity (3.2Ah), dimensions and connection type (Faston 4.8 mm) with your old battery before purchasing to ensure compatibility.
What charging parameters apply to this battery?
Float charge: The recommended voltage at 20 °C is between 13.5 V and 13.8 V.
Cycle charging: For occasional cyclic charging, a voltage between 14.4 V and 15.0 V is recommended.
Maximum charging current: The charging current should not exceed 0.96 A to maximise battery life.
What does the Faston 187 connection type mean?
Faston 187 refers to the type of connection. These are flat blade connectors with a width of 4.8 mm (0.187 inch). Cables are simply plugged onto these contacts, which enables quick and tool-free installation.
Properties
| Capacity: | 3.2Ah |
|---|---|
| Tension: | 12V |
| VDS: | G104100 |
Documents 1