Description

Product information

The XCELL XP1.2-12 is a compact 12-volt AGM lead-acid battery with a nominal capacity of 1.2 Ah. It reliably supplies energy in safety-related devices and industrial applications, impresses with easy integration and defined charging parameters for standby and cyclic operation.

Highlights at a glance

  • Compact and lightweight: 97 x 43 x 58 mm at approx. 0.54 kg
  • VdS approved: G 114095 for safety applications
  • Maintenance-free thanks to AGM technology and valve-regulated construction
  • Clear charging windows: Float 13.60 to 13.80 V, Cycle 14.50 to 14.90 V
  • Solid power reserve: up to 18 A discharge current for 5 seconds

Use and Performance

The XP1.2-12 is designed for alarm and security technology, emergency lighting, communication and measuring devices as well as small control units. The internal impedance of approx. 90 mΩ supports stable voltage supply, even during short load peaks. The permissible discharge range from −15 °C to +50 °C enables operation in different environments.

Efficiency and Service Life

In float operation, an expected service life of 3 to 5 years at 20 °C is envisaged. The self-discharge is low: at 25 °C approx. 91 percent capacity remains after 3 months, 82 percent after 6 months and 65 percent after 12 months of storage. This means the battery remains reliably available even after idle periods.

Installation and Charging Recommendations

The battery has T1 terminals for quick, secure installation. For standby operation, a charging voltage of 13.60 to 13.80 V at 25 °C with temperature compensation of −18 mV per °C is recommended. In cyclic operation, 14.50 to 14.90 V at 25 °C with −30 mV per °C compensation applies. The maximum charging current is 0.36 A.

Features

 
ModelXCELL XP1.2-12 VdS
Battery typeVRLA AGM (safety technology)
Nominal voltage (V)12
Capacity (Ah)1.2 (at 20h rate)
Maximum discharge current18A (for 5 seconds)
Charging voltage (standby charge)13.5V - 13.8V
Charging voltage (cyclic operation)14.4V - 15.0V
Operating temperature (°C)Charge: 0 ~ 40 / Discharge: -20 ~ 50
Storage temperature (°C)-20 ~ 40
Service lifeup to 5 years (EUROBAT: Standard Commercial)
Dimensions (L/W/H, mm)97 x 43 x 58
Weight (kg)approx. 0.57
ConnectionFaston 187 (4.8 mm)
CertificationsVdS, ISO9001, CE, UL
 

FAQs about the XCELL XP1.2-12

What is the expected service life of the XP1.2-12 in standby operation?

At 20 °C, 3 to 5 years in float operation is envisaged. Regular functional checks and appropriate charging voltage increase availability.

For which applications is the XP1.2-12 battery suitable?

Preferred for alarm and signalling systems, emergency lighting, communication and measuring devices as well as compact controllers with 12-volt supply.

Which charging voltages should be used?

In float charge operation, the voltage should be between 13.60 V and 13.80 V at 25 °C. In cyclic operation, the recommended voltage range is 14.50 V to 14.90 V. Please note the temperature compensation.

What is the self-discharge rate?

At 25 °C, approx. 91 percent of the capacity remains after 3 months, approx. 82 percent after 6 months, and approx. 65 percent after 12 months storage.

Which terminals are present on the battery?

T1 flat plug terminals for quick integration into devices and assemblies.

Which VdS approval does the battery have and is it system-bound?

The battery is VdS-approved under number G114095 and the approval is not system-bound.


 

Properties

Capacity: 1.2Ah
Tension: 12V
VDS: G114095

Documents 2

Reviews 0

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Customers also bought

XCEXP2.312
XCELL XP2.3-12 lead-acid battery with VdS approval - 12 V and 2.3 Ah

The XCELL XP2.3-12 is a slim 12 volt AGM lead-acid battery with a nominal capacity of 2.3 Ah. It provides reliable power supply in safety-relevant and industrial applications and, with VdS G 115071, fulfils the requirements for professional use.Highlights at a glanceReliable capacity: 2.3 Ah at 20 hours to 10.5 VVdS recognised: G 115071, additionally UL and CE, manufactured to ISO 9001Power reserve: up to 34.5 A discharge current for 5 secondsSlim design: 178 x 35 x 67 mm at approx. 0.9 kgMaintenance-free: valve-regulated AGM technology with ABS housingLow self-discharge: 91 per cent residual capacity after 3 months at 25 °CApplications and performanceThe XP2.3-12 is suitable for alarm and security equipment, emergency lighting, fire alarm systems, communications and measuring devices, as well as control and regulation technology. The internal impedance of approx. 60 mΩ (fully charged, 25 °C) supports stable voltage supply, even during short-term load peaks.Charging parameters and operationFor standby operation, 13.60 to 13.80 V at 25 °C with temperature compensation of minus 18 mV per °C is recommended. In cyclic operation, the end-of-charge voltages are 14.50 to 14.90 V at 25 °C, compensation minus 30 mV per °C. The maximum charging current is 0.69 A. The permissible temperature range is from minus 15 °C to plus 50 °C during discharge, minus 10 °C to plus 50 °C during charging, and minus 20 °C to plus 50 °C for storage.Dimensions and connectionThe T1 flat plug connectors made of copper allow quick integration into existing systems. The compact, elongated design means the battery can be positioned particularly well in narrow housings and racks.Features  ModelXCELL XP2.3-12 VdS Battery typeVRLA AGM (safety technology) Nominal voltage (V)12 Capacity (Ah)2.3 (at 20h rate) Maximum discharge current34.5A (for 5 seconds) Charging voltage (float charge)13.5V - 13.8V Charging voltage (cyclic use)14.4V - 15.0V Operating temperature (°C)Charging: 0 ~ 40 / Discharge: -20 ~ 50 Storage temperature (°C)-20 ~ 40 Service lifeup to 5 years (EUROBAT: Standard Commercial) Dimensions (L/W/H, mm)178 x 35 x 66 Weight (kg)approx. 0.94 ConnectionFaston 187 (4.8 mm) CertificationsVdS, ISO9001, CE, UL  FAQs about the XCELL XP2.3-12What is the expected service life for the XP2.3-12 in standby operation?At 20 °C, the XP2.3-12 battery is designed for 3 to 5 years in float operation. Regular test cycles and correct charging voltage increase availability.For which applications is the XP2.3-12 battery suitable?Preferred for safety-related systems such as fire alarm systems and intruder alarm systems, emergency lighting, communications and measuring devices, as well as controls with 12 volt supply.Which charging voltages must be observed?Float 13.60 to 13.80 V at 25 °C, cyclic operation 14.50 to 14.90 V. Please observe the respective temperature compensation.What is the self-discharge rate?At 25 °C, about 91 per cent capacity remains after 3 months, 82 per cent after 6 months and 65 per cent after 12 months of storage.Which connectors are present on the XP2.3-12?The XP2.3-12 is equipped with T1 flat plug connectors made of copper for quick, secure installation. 

XCEXP712
XCELL XP7-12 AGM industrial battery - 12 V and 7.0 Ah

The XCELL XP7-12 is a valve-regulated AGM battery with 12 volts and 7 Ah nominal capacity (C20). It impresses with its compact dimensions, high operational reliability and long service life. Thanks to its robust design and low self-discharge, it is ideal for use in safety and emergency power systems, medical technology, measurement and control technology, telecommunications and numerous mobile and stationary applications.Highlights at a glanceCompact performance: 12 V, 7.0 Ah (20h)Flexible use: Any operating position possible (except permanently overhead)Durable: up to 5 years design life at 20 °CHigh reliability: Low self-discharge <3 % per month at 25 °CRobust housing: ABS UL94 HBReliable power supply for a wide range of applicationsThe XCELL XP7-12 delivers constant performance even under demanding conditions. The AGM technology ensures efficient gas recombination, making the battery virtually maintenance-free. With a maximum discharge current capacity of 105 A (5 seconds), it is also suitable for applications with short-term peak loads.Efficiency meets service lifeIn standby operation, the battery should be charged with a charging voltage of 2.25–2.30 V/cell. For cyclic operation, a charging voltage of 2.45–2.50 V/cell is recommended. The temperature compensation is –3 mV/cell/°C in standby operation and –4 mV/cell/°C in cycle operation. The recommended maximum current is 0.3C (approx. 2.1 A). In cycle use, depending on the depth of discharge, the battery achieves several hundred charge and discharge cycles.Technology for flexible applicationsThe operating temperature range of the cells when charging is between –15 °C and +50 °C. When discharging, it is –20 °C to +60 °C and for storage –20 °C to +50 °C. T1 or T2 plug-in connections are available for the electrical connection. The recommended tightening torque for this is between 2 and 3 Newton metres. Each cell is additionally equipped with a safety valve, which further increases operational reliability.Features  ModelXCELL XP7-12 Battery typeVRLA AGM (standby / general purpose) Nominal voltage (V)12 Capacity (Ah)7.0 (at 20h rate) Maximum discharge current105A (for 5 seconds) Charging voltage (float charge)13.5V - 13.8V Charging voltage (cyclic operation)14.4V - 15.0V Operating temperature (°C)Charging: 0 ~ 40 / Discharging: -20 ~ 50 Storage temperature (°C)-20 ~ 40 Service lifeup to 5 years (EUROBAT: Standard Commercial) Dimensions (L/W/H, mm)151 x 65 x 100 Weight (kg)approx. 2.1 ConnectionFaston 187 (4.8 mm) CertificationsISO9001, CE, UL  FAQ about the XCELL XP7-12 industrial batteryFor which applications is the XP7-12 ideally suited?The XCELL XP7-12 is predestined for emergency power supply, safety and fire alarm systems, medical technology, telecommunications, measurement and control technology as well as mobile devices with cyclic energy requirements.How cycle-resistant is the XP7-12?At 30 % depth of discharge, the battery achieves over 1,000 charge and discharge cycles. At higher depths of discharge, the service life is reduced accordingly, but remains in the range of several hundred cycles.What are the special safety features?The battery is equipped with overpressure valves. Like all VRLA batteries, it can emit small amounts of hydrogen. It should therefore not be used in airtight enclosures and adequate ventilation must be ensured.Which chargers are suitable for the XP7-12?Chargers with constant voltage, designed for VRLA AGM batteries, are recommended. The correct setting of the charging voltage and temperature compensation is crucial for a long service life.How is the battery installed?The battery can be installed in any position except permanently upside down. The connection is made via T1 or T2 plug-in connectors with a tightening torque of 2–3 Nm. 

YUANP12/12
Yuasa Lead-acid battery with 12V and 12Ah - NP12-12 VDS

The Yuasa NP12-12 VDS is a high-quality, valve-regulated lead acid battery (VRLA) with a nominal voltage of 12 volts and a capacity of 12 Ah. Equipped with maintenance-free AGM technology and VdS certification, this battery provides a reliable and long-lasting power supply for safety-critical and industrial applications. Whether in standby mode or in cyclical operation, the NP12-12 meets the highest quality and safety standards.Highlights at a glanceHigh capacity: 12 Ah at 12 V for long-lasting power supply.VdS-certified: Ideal for fire and burglar alarm systems.Maintenance-free: Leak-proof AGM technology with > 99 % gas recombination.High current carrying capacity: Up to 360 A discharge current for 1 second.Flexible mounting: Operation in all positions (except permanently overhead).Durable: EUROBAT class “Standard Commercial” with up to 5 years service life.Powerful performance for safety-critical applicationsThe NP12-12 delivers 12 Ah with a 20-hour discharge (to 1.75 V/cell) and 11.1 Ah with a 10-hour discharge (to 1.8 V/cell). With a maximum discharge current of 360 A for 1 second and 75 A for 1 minute, this battery is also ideally suited for short-term power peaks.Robust technology for demanding environmentsThanks to VRLA technology (Valve Regulated Lead Acid) with AGM system (Absorbent Glass Mat), the NP12-12 is absolutely maintenance-free and leak-proof. The battery features self-closing low-pressure release valves for safe pressure equalisation within the cells. The internal resistance is 44.39 mΩ according to EN IEC 60896-21, the short-circuit current is 320 A. The low self-discharge of approx. 3 % per month allows long-term storage with high operational readiness. The robust ABS housing can also be supplied in a flame-retardant version (UL94:V0) on request.Features  ModelYuasa NP12-12 VDS Battery typeVRLA AGM (maintenance-free) Nominal voltage (V)12 Capacity (Ah)12 (at 20h rate) Maximum discharge current120A (for 5 seconds) Charging voltage (standby charge)13.65V (±1%) Charging voltage (cyclic operation)14.7V (±3%) Operating temperature (°C)-15 ~ 50 Storage temperature (°C)-20 ~ 50 Service lifeUp to 5 years (according to Yuasa design) Dimensions (L/W/H, mm)151 x 98 x 94 Weight (kg)4.0 ConnectionFaston 6.3mm CertificationsIEC 60896-21+22, VdS, UL  FAQs about the Yuasa NP12-12 lead-acid batteryFor which applications is the NP12-12 suitable?The battery is ideally suited for:VdS-compliant fire and burglar alarm systemsUninterruptible power supplies (UPS)Safety lightingTelecommunicationsControl and regulation technologyMedical devicesIs the battery maintenance-free?Yes, thanks to AGM technology the battery is completely maintenance-free and leak-proof.What is the service life of the NP12-12?The service life is up to 5 years at 20 °C and corresponds to the EUROBAT category “Standard Commercial”.Can the battery be installed flexibly?Yes, the battery can be operated in all orientations, except for permanently upside-down installation.Which charging parameters (float vs. cycle) apply?Float charging voltage (20 °C): approx. 13.65 V (2.275 V/cell), compensation –3 mV/cell/°CBoost/cycle charge: approx. 14.5 V (2.42 V/cell), compensation –4 mV/cell/°CCyclic charge limitation: max. 3 A (~0.25 C)What temperature ranges and storage conditions apply?Charging: −15 °C to +50 °CDischarge: −20 °C to +60 °CStorage (fully charged): −20 °C to +60 °CSelf-discharge: approx. 3 % per month at 20 °C

XCEXP1212F2
XCELL XP12-12F2 lead-acid battery lead-acid battery with VdS approval - 12 V and 12 Ah

The XCELL XP12-12F2 is a reliable, valve-regulated lead-acid battery with 12 volts and 12 Ah capacity. With Faston 6.3 mm connectors, compact dimensions and VdS certification (G120034), it is ideal for safety-critical applications such as fire and burglar alarm systems, UPS systems as well as medical and industrial devices. Its spill-proof AGM technology ensures maintenance-free and long-lasting energy supply.Highlights at a glanceVdS certified: Tested safety according to VdS G120034Compact design: Only 151 x 98 x 95 mm at approx. 4.1 kg weightReliable performance: 12 Ah capacity at 20-hour dischargeHigh discharge current: Up to 180 A (5 sec.) for peak loadsDurable: Up to 5 years of service life at 25 °C in standby modePowerful performance for challenging applicationsThanks to its robust construction and uniform current output, the XP12-12F2 is suitable for a wide range of applications: from safety-relevant systems and telecommunications to medical devices. The Faston connectors (6.3 mm) enable easy integration into existing systems. Even during short-term peak loads, the battery reliably delivers energy with up to 180 A discharge current for 5 seconds.Efficient energy and reliable service lifeAGM technology ensures maintenance-free operation and high reliability. With a float lifetime of up to 5 years (at 25 °C), the battery is characterised by a low self-discharge rate of less than 3 % per month, making it ready for immediate use even after long storage. It also impresses with good performance at extreme temperatures from -15 °C (charging) to +60 °C (discharging).Technology for industrial and safety-critical applicationsThe XP12-12F2 features a flame-retardant ABS housing (according to UL94-HB/UL94-V0) and meets international standards such as ISO 9001, ISO 14001 and OHSAS 18001. The charging voltage in standby operation is 2.25 – 2.30 V/cell (corresponds to 13.5 – 13.8 V) and in cycle operation 2.45 – 2.50 V/cell (corresponds to 14.7 – 15.0 V) at an ambient temperature of 25 °C. Automatic temperature compensation from –3 to –4 mV/°C/cell is integrated.Features  ModelXCELL XP12-12F2 VdS Battery typeVRLA AGM (safety technology) Nominal voltage (V)12 Capacity (Ah)12 (at 20h rate) Maximum discharge current180A (for 5 seconds) Charging voltage (float charge)13.5V - 13.8V Charging voltage (cycle operation)14.4V - 15.0V Operating temperature (°C)Charging: 0 ~ 40 / Discharging: -20 ~ 50 Storage temperature (°C)-20 ~ 40 Service lifeup to 5 years (EUROBAT: Standard Commercial) Dimensions (L/W/H, mm)151 x 98 x 100 Weight (kg)approx. 3.6 ConnectionFaston 250 (6.35 mm) CertificationsVdS, ISO9001, CE, UL  FAQs about the XCELL XP12-12F2 lead-acid batteryHow long does the XCELL XP12-12F2 last in standby operation?Under ideal conditions (25 °C ambient temperature), the expected lifetime in standby operation is up to 5 years.Is the battery VdS certified?Yes, the battery holds the VdS approval with the number G120034 and is thus suitable for safety-relevant applications.In which temperature ranges can the battery be used?The battery is designed for a charging range from –15 °C to +50 °C and a discharging range from –20 °C to +60 °C.How high is the self-discharge?At 25 °C, the self-discharge of the battery is below 3 % per month. It is recommended to recharge the battery if stored for more than six months.Which charging parameters must be observed?For standby operation, the charging voltage is 13.5–13.8 V. In cycle operation, it should be 14.7–15.0 V. Temperature compensation is –3 mV/°C/cell in standby operation and –4 mV/°C/cell in cycle operation.For which applications is this battery particularly suitable?It is suitable for photovoltaic systems, UPS systems, emergency lighting, telecommunications and security technology, alarm and hazard detection systems as well as for hobby and camping. However, it is not suitable for starting or traction applications.

XCEXP712F2
XCELL XP7-12F2 lead-acid battery with 12 V and 7 Ah

The XCELL XP7/12F2 convinces as a reliable 12-volt lead-acid battery with 7.2 Ah (20h rate) capacity, robust AGM technology and compact dimensions. Equipped with Faston connectors, this battery is ideal for security and emergency power systems, telecommunications and mobile devices. With a service life of up to 10 years in standby operation, it provides a stable power supply with minimal maintenance.Highlights at a glanceRobust capacity: 7.2 Ah with 20-hour discharge for various areas of applicationLong service life: Up to 10 years standby life at 20 °CHigh discharge reserves: Maximum discharge currents up to 108 A for 5 secondsTemperature resistant: Powerful from -15 °C to +50 °CCompact design: Only 151 x 65 x 100 mm at approx. 2.26 kgStrong performance for demanding areas of applicationThe XCELL XP7/12F2 is the ideal solution for applications that require a compact design with high energy density. Typical areas of use are uninterruptible power supplies (UPS), safety-related lighting systems, medical devices, alarm systems and other industrial applications. Thanks to its Absorbent Glass Mat technology, the battery offers reliable performance even in short-term peak loads.Efficient energy for continuous operationThis battery is characterised by a low self-discharge of only about 9 % in 3 months at 25 °C, making it quickly ready for use even after longer idle periods. Its charging characteristic supports both standby operation with a recommended voltage of 13.60 to 13.80 V and cyclic operation with 14.50 to 14.90 V. With a recommended max. charging current of 2.16 A, the battery remains safe and efficient in operation.Reliable technology for the highest demandsAGM technology ensures leak-proof, maintenance-free operation with an internal gas recovery system. The XCELL XP7/12F2 can be installed in any orientation (except upside down) and reliably withstands temperatures between -15 °C and +50 °C in discharge operation. Its high cycle stability and UL and CE certifications emphasise its suitability for demanding industrial environments.Features  ModelXCELL XP7-12F2 Battery typeVRLA AGM (standby / general purpose) Nominal voltage (V)12 Capacity (Ah)7.0 (at 20h rate) Maximum discharge current105A (for 5 seconds) Charging voltage (trickle charge)13.5V - 13.8V Charging voltage (cyclic operation)14.4V - 15.0V Operating temperature (°C)Charge: 0 ~ 40 / Discharge: -20 ~ 50 Storage temperature (°C)-20 ~ 40 Service lifeup to 5 years (EUROBAT: Standard Commercial) Dimensions (L/W/H, mm)151 x 65 x 100 Weight (kg)approx. 2.1 ConnectionFaston 250 (6.35 mm) CertificationsISO9001, CE, UL  FAQs about the XCELL XP7/12F2 lead-acid batteryHow long is the service life of the battery?The XCELL XP7/12F2 is designed for a service life of up to 10 years in standby operation at 20 °C.What is the battery particularly suitable for?It is ideally suited for applications such as UPS systems, emergency lighting, medical devices, telecommunications systems and mobile electronic devices.Can the battery also be used at low temperatures?Yes, the battery operates reliably in a discharge temperature range from -15 °C to +50 °C.Does the battery require regular maintenance?No, the battery is maintenance-free thanks to its sealed, valve-regulated AGM design.Which charging parameters must be observed?For standby operation, a charging voltage of 13.60 – 13.80 V is recommended, for cyclic operation 14.50 – 14.90 V. The maximum charging current should not exceed 2.16 A. 

XCEXP3.412
XCELL XP3.4-12 lead-acid battery with VdS approval - 12 V and 3.4 Ah

The XCELL XP3.4-12 is a compact 12-volt AGM lead-acid battery with a nominal capacity of 3.4 Ah. It delivers stable performance in safety-relevant and industrial applications and can be integrated quickly thanks to T1 flat plug connections. VdS approval and production in accordance with ISO 9001 emphasise its suitability for professional use.Highlights at a glance3.4 Ah with 20-hour discharge up to 10.5 VVdS recognised, additionally UL and CELow internal resistance of approx. 45 mΩ for reliable power outputSlim format 134 x 67 x 66.5 mm at approx. 1.20 kgMaintenance-free thanks to VRLA-AGM and robust ABS housingPerformance for demanding applicationsThe XP3.4-12 ensures a reliable 12 V supply for fire alarm and intruder alarm systems, emergency and safety lighting, control and regulation technology as well as measuring and communication devices. Even short-term load peaks are absorbed in a stable manner.Efficiency and service lifeThe usable capacity is maintained over a wide temperature range: At 40 °C it is 103 per cent, at 25 °C it is 100 per cent and at 0 °C it is still 86 per cent. The VRLA-AGM technology ensures minimal maintenance and constant performance throughout the entire service life.Technology and installationT1 flat plug connections enable fast, reverse polarity protected integration. In standby mode, a charging voltage of 13.5 to 13.8 V at 25 °C with temperature compensation of minus 20 mV per °C is recommended. In cycling mode, 14.4 to 15.0 V at 25 °C with minus 30 mV per °C. The initial charging current in cycling mode should be less than 1.02 A.Features  ModelXCELL XP3.4-12 VdS Battery typeVRLA AGM (safety technology) Nominal voltage (V)12 Capacity (Ah)3.4 (at 20h rate) Maximum discharge current51A (for 5 seconds) Charging voltage (trickle charge)13.5V - 13.8V Charging voltage (cycle operation)14.4V - 15.0V Operating temperature (°C)Charging: 0 ~ 40 / Discharging: -20 ~ 50 Storage temperature (°C)-20 ~ 40 Service lifeup to 5 years (EUROBAT: Standard Commercial) Dimensions (L/W/H, mm)134 x 67 x 66 Weight (kg)approx. 1.3 ConnectionFaston 187 (4.8 mm) CertificationsVdS, ISO9001, CE, UL  FAQs about the XCELL XP3.4-12What is the XP3.4-12 battery particularly suitable for?For safety systems such as fire alarm and intruder alarm systems (BMA and EMA), emergency and safety lighting, controls, communication and measuring devices, and other 12-volt systems with moderate to medium loads.Which charging voltages must be observed?In standby mode, the voltage at 25 °C is 13.5 to 13.8 V. In cycling mode it is between 14.4 and 15.0 V. Please note the respective temperature compensation.Which connections are available on the XP3.4-12?T1 flat plug connections for quick, reverse polarity protected installation in existing cable assemblies.Is the battery maintenance-free?The VRLA-AGM technology enables leak-proof, low-gassing and practically maintenance-free operation.Are there different versions with and without VdS approval?Yes, in addition to the VdS version with the designation G 125002, there are dealer offers for the standard version without VdS approval, which should be taken into account when selecting the product.How does the temperature affect the capacity?The capacity depends on temperature and at 40 degrees Celsius is about 103 percent of the nominal value, at 25 degrees Celsius 100 percent and at 0 degrees Celsius 86 percent.