The VISION RBC133 is a high-quality, ready-to-install replacement battery cartridge designed as a direct and reliable replacement for the original APC RBC133 Cartridge. Fitted with high-performance, valve-regulated VRLA batteries, this cartridge offers a cost-effective and safe solution to restore the full performance of your APC Smart UPS system. Equipped with maintenance-free AGM technology, this product ensures fail-safe power for your business-critical applications.
Highlights at a glance
- 100% Compatible: Developed as a precision-fit replacement cartridge for APC RBC133, enabling simple and fast hot swap installation.
- Plug and Play Installation: The cartridge comes fully assembled and wired for a replacement in minutes without interrupting operation.
- High Reliability: Uses only high-quality AGM batteries that are optimised for demanding UPS operation.
- Maintenance-Free: The leakproof AGM technology renders any battery maintenance unnecessary over the entire service life.
- Durable: Designed for long service life in standby operation to protect your systems reliably for years.
- Economical Solution: Provides the same performance and safety as the original at an attractive price.
Powerful performance for safety-critical applications
The VISION RBC133 Cartridge is designed to meet the demanding requirements of APC Smart UPS systems of the 3000VA class. The installed batteries are high-current capable and can provide the required power immediately in the event of a power failure, ensuring your connected servers, network storage and other critical devices can be safely shut down or continue operation. The stable and reliable performance safeguards your valuable hardware against damage from power fluctuations and outages.
Robust technology for demanding environments
The batteries used in the RBC133 Cartridge are based on proven VRLA technology (Valve Regulated Lead Acid) with an AGM system (Absorbent Glass Mat), in which the electrolyte is securely embedded in a glass fibre mat. This makes the batteries completely leakproof and allows operation in any position. Low self-discharge ensures long shelf life and readiness for use. The robust ABS plastic battery case provides excellent protection against mechanical impact.
Features
| Model | VISION RBC133 replacement battery cartridge |
| Battery type | VRLA AGM (UPS replacement battery cartridge) |
| Contents | Pre-assembled cartridge, Plug & Play |
| Nominal voltage (V) | 48 (System voltage) |
| Capacity (Ah) | 5 (Typical value) |
| Charging voltage (float) | 54.0V - 55.2V (System) |
| Charging voltage (cyclic operation) | 57.6V - 60.0V (System) |
| Operating temperature (°C) | Charge: 0 ~ 40 / Discharge: -20 ~ 50 |
| Storage temperature (°C) | -20 ~ 40 |
| Service life | up to 5 years (EUROBAT: Standard Commercial) |
| Dimensions (L/W/H, mm) | Compatible with original dimensions |
| Weight (kg) | approx. 11.5 |
| Connection | Matching APC system plug |
| Compatibility (excerpt) | APC SMT3000RMT2U, SMX3000RMLV2U |
FAQs about the VISION RBC133 replacement battery cartridge
For which UPS models is this cartridge suitable?
The VISION RBC133 cartridge is designed to replace the original APC RBC133 battery unit and is compatible, among others, with the following APC Smart UPS models: SMT3000RMT2U, SMX2000RMLV2U, SMX3000RMHV2U, SMX3000RMLV2U. Please check the exact designation of your UPS system before purchase.
Is replacing the battery complicated?
No, replacement is very simple and can be carried out during operation (hot swap) without technical expertise. The APC UPS systems have a readily accessible battery compartment. You simply need to remove the old cartridge, disconnect the plug, connect the new VISION RBC133 cartridge and slide it back in.
Do I need to set anything on the UPS after replacement?
After inserting the new cartridge, the UPS usually recognises the replacement automatically. It is recommended to note the replacement date of the battery via the software or the display and to perform a self-test function. Runtime calibration can be useful to ensure an accurate remaining run time display.
Is using a replacement cartridge from third-party manufacturers safe?
Yes, absolutely. VISION is a renowned manufacturer of high-quality AGM batteries. Our RBC133 cartridge is expertly assembled, tested and uses only quality-checked batteries designed for use in UPS systems to ensure maximum safety.
What service life does the VISION RBC133 replacement cartridge have?
The service life of the installed batteries in typical standby operation in a UPS system at 20 °C is up to 5 years. The actual service life may be affected by conditions such as ambient temperature and the frequency of power failures.
What do I need to observe when disposing of the old cartridge?
Lead batteries are hazardous waste and must not be disposed of with household waste. You can dispose of your old cartridge free of charge and in an environmentally friendly way at municipal collection points, recycling centres or at any retailer who sells starter batteries.
Reviews 0
Login